A runtime worksheet

How to size backup power

The useful question is not “how many watts does this station advertise?” It is “how many hours will my actual loads run, and will the inverter start the hardest one?” This page is a worksheet, not a lab report.

Affiliate disclosure. This page is a sizing explainer. Product links, when they appear, follow the same disclosure as the rest of the site. No tracked checkout URLs are live yet.

The only formula you need

Estimated hours ≈ (listed watt-hours × 0.85) ÷ average watts of the loads that are actually on.

The 0.85 factor is a planning cushion for inverter losses and for not running the battery to empty. It is not a measurement of any one brand. In cold garages, at high continuous loads, or on a unit with high idle draw, real runtime can be shorter. Makers also publish their own “fridge for X hours” figures; those are usually best-case tests at a set room temperature, and we treat them as claims.

Two different numbers, often mixed up

NumberWhat it answersIf it is too small
Capacity (Wh or kWh) How long you can run The unit shuts off while the load is still modest
Continuous output (W) What you can run at the same time The inverter overloads, even if the battery is full
Surge / peak output (W) Whether a motor will start A fridge, pump, or AC compressor clicks and trips the unit
Voltage (120 V vs 240 V) Whether the outlet matches the load A 240 V well pump or some shop tools will not run no matter how big the pack is

Typical load ranges (not measurements)

These are commonly cited household ranges, not readings from a particular house. The right number is whatever your device’s nameplate or a plug-in watt meter says. Motors (fridges, pumps, window AC, some furnaces) draw a short startup surge several times their running watts.

LoadTypical running drawWhat to watch
LED lights (a few rooms) 40–80 W Easy. Almost any station can do this all night.
Cable modem + Wi-Fi router 15–30 W Small, but you want a clean handoff so the network does not drop. See the internet guide.
Starlink Standard-class kit (dish + router + power supply) Often cited around 75–100 W average AC input, depending on generation and sky conditions Confirm in the Starlink app for your kit. Rain, obstruction, and heater use can push draw up. Details in Starlink and internet backup.
Laptop + phone charging 30–100 W while charging Bursty. USB-C ports on the station are more efficient than an AC brick when they can supply the laptop.
Modern refrigerator 100–200 W while the compressor runs; much less while it rests. Daily energy is often 1–2 kWh Startup surge is commonly 600–1,200 W. Keep the door shut. A 1 kWh station can cover a night if little else is on; a 2–3 kWh station is more comfortable.
Chest freezer Similar running draw to a fridge; opens less often A full freezer holds temperature longer than a half-empty fridge. Still budget the compressor surge.
CPAP Often 30–60 W without a humidifier; higher with heated tubing or a humidifier Read the adapter. Some people run a DC cable and skip the inverter losses. This is not medical advice — confirm with the machine’s manual and your clinician.
Window air conditioner (small) 500–1,000 W running for many 5,000–8,000 BTU units Surge is higher. A 1 kWh / 1,800 W station may start one and then empty the pack in an hour or two. Plan capacity accordingly, or skip AC on battery.
Gas furnace blower (not the heat itself) Often 400–800 W for the fan, plus a small draw for controls The furnace still needs its fuel. Confirm the nameplate. Some control boards are picky about inverter waveform — check the furnace manual.
Sump pump Often 750–1,500 W while running Intermittent, but it must start reliably in a storm. Surge and a GFCI-safe hookup matter more than pretty runtime math.
Well pump Wide range: many 120 V jet pumps are several hundred to 1,500+ W; 240 V submersibles can be 1,500–3,000 W or more This is the load that sends people to a 240 V station or a generator. Do not assume a compact 120 V unit can run the well.
Microwave, coffee maker, toaster, hair dryer 800–1,800 W, short use Fine as a brief luxury on a 2 kW+ inverter. Terrible as a plan for stretching overnight capacity.
Central air, electric range, electric dryer, tankless electric water heater Typically thousands of watts, often 240 V Outside what most portable stations should be asked to do. This is generator or installed-battery territory, with a transfer switch.

Worked examples (planning math only)

These use the 85% rule and mid-range draws. They are illustrations, not promises.

GoalAssumed average loadOn a 1,024 Wh station (≈870 Wh usable)On a 2,048 Wh station (≈1,740 Wh usable)On a 5,000 Wh station (≈4,250 Wh usable)
Internet only (router + modem) 25 W ~35 hours ~70 hours Many days, if idle drain stays low
Starlink Standard-class kit 90 W (midpoint of the commonly cited 75–100 W band) ~9–10 hours ~19 hours ~47 hours
Starlink + modern fridge (averaged, door shut) 90 W + ~80 W average ≈ 170 W ~5 hours — tight for overnight ~10 hours — a night, not a day ~25 hours
Fridge + lights + router, no Starlink ~150 W averaged ~6 hours ~12 hours ~28 hours
Small window AC, running hard 800 W ~1 hour ~2 hours ~5 hours

The lesson in that last row is the one marketing pages skip: air conditioning is a capacity killer. A 5 kWh pack that can start a window unit still may not cool a bedroom all night.

A simple way to build your list

  1. Write down only the loads you will actually run in an outage. Be harsh. A coffee maker is optional. A fridge, a sump pump, a CPAP, or a well usually is not.
  2. Put a running-watt and, for motors, a startup-watt number next to each item. Use the nameplate or a watt meter if you can. Guessing high is safer than guessing low.
  3. Add the running watts of everything that will be on at once. That sum must stay under the station’s continuous output, with room to spare.
  4. Check the single hardest startup against the station’s surge rating.
  5. Estimate average watts over a night (a fridge is not on at full power all night; a Starlink kit closer to is). Then apply the formula at the top.
  6. Decide how you will recharge: wall power between outages, a car charger, solar panels in sun, or a generator. A station you cannot refill is a one-shot battery.

Who this worksheet is for

Who should skip this approach — and maybe skip a power station

Safety. Sizing a battery does not make you an electrician. Any hookup to a home panel needs a listed transfer switch or interlock and a licensed electrician. Never backfeed a wall outlet. Keep gas generators outdoors and downwind. This page is not medical or emergency-planning advice.